Method Statement Template

Roofing Method Statement Template 2026

Create OHSA-compliant roofing method statements for South African tenders. Covers Roof structure installation, Roof sheeting installation, Tile installation, and more.

2-Minute Generation

AI generates your complete roofing method statement in under 2 minutes.

OHSA Compliant

Meets Construction Regulations 2014 and OHSA Construction Regulations 2014 requirements.

Export Ready

Download as PDF or Word. Ready for tender submission.

What's Included in a Roofing Method Statement

Standard Sections

  • Roof System Specification
  • Access and Fall Protection
  • Installation Sequence
  • Waterproofing Procedures
  • Flashing Details
  • Quality Control Measures
  • Weather Contingencies
  • Safety Measures

Common Activities Covered

  • Roof structure installation
  • Roof sheeting installation
  • Tile installation
  • Waterproofing membrane application
  • Flashing installation
  • Gutter and downpipe installation
  • Roof repairs and maintenance
  • Skylight installation

Roofing Hazards & Safety Requirements

Common Hazards

  • Falls from height
  • Falls through fragile materials
  • Slips on inclined surfaces
  • Burns from hot bitumen
  • Manual handling injuries
  • Weather exposure
  • Struck by falling materials
  • Electrical hazards (near power lines)

Required PPE

  • Hard hat
  • Safety boots (non-slip)
  • Safety harness and lanyard
  • High-visibility vest
  • Gloves
  • Safety glasses
  • Knee pads

Applicable Regulations & Standards

OHSA Construction Regulations 2014
Fall Protection Plan requirements
SANS 10400-L (Roofs)
Manufacturer specifications

CIDB Classes applicable: GB, SB

Roofing Method Statements in South Africa

Roofing work in South Africa is governed by the OHSA Construction Regulations 2014 (particularly Regulation 10 for fall protection), SANS 10400-L (Roofs) and SANS 10400-T (Fire protection). Government housing projects (under NHBRC warranty), public buildings, and municipal facilities all require method statements detailing every stage from structural support through to waterproofing completion. Falls from roofs are the single leading cause of construction fatalities in SA — tender evaluations heavily weight the fall protection plan. Roofing contractors may need CIDB class GB (General Building) for complete roof structures, or a combination with specialist waterproofing registration. The NHBRC (National Home Builders Registration Council) registration is mandatory for residential projects. For industrial and commercial roofing, tenders frequently reference SANS 10137 (steel roofing and cladding), SATAS (South African Technical Auditing Services) for waterproofing membrane approval, and manufacturer-specific installation requirements. Waterproof guarantees of 10-15 years are standard on government tenders.

Method Statement Writing Tips for Roofing

Tip 1: Detail your fall protection plan as a standalone section — Reg 10 requires this for all work above 2m. Show edge protection, safety net, or harness systems for each roof area

Tip 2: For sheet metal roofing, specify fixing patterns per SANS 10137 including fastener type, spacing, and washer specification for the wind zone and building height

Tip 3: Address weather restrictions: no torch-on waterproofing below 5°C or on wet substrates. Specify your moisture testing method (electrical impedance or calcium chloride)

Tip 4: Include your quality hold points: structural frame check → underlayment inspection → sheeting/tiling completion → waterproofing test → snag inspection

Tip 5: For flat roof waterproofing, specify the complete system: primer → reinforcing membrane → waterproofing layers → protection board → drainage test. Reference SATAS approval numbers

Common Mistakes in Roofing Method Statements

Not submitting a standalone fall protection plan — Reg 10 requires this as a separate document, not just a section in the method statement

Specifying inadequate fixing for the wind zone: SA coastal areas (Cape Town, Durban) require heavier fixings per SANS 10160-3 wind loading calculations

Failing to include a waterproof guarantee per tender requirements — government tenders typically require 10-year guarantees backed by the membrane manufacturer

Using non-SATAS-approved waterproofing membranes — government specifications routinely require SATAS certification for flat roof application systems

Not addressing fragile roof access for maintenance projects — existing asbestos, fibre cement, and aged steel roofs are fragile until proven otherwise

Key Legislation for Roofing Method Statements

Regulation / StandardRequirement
OHSA Construction Regulations 2014, Reg 10Fall protection: requires a written fall protection plan for all work above 2m. Must detail edge protection, safety nets, or fall arrest systems for every roof zone and phase of work.
SANS 10400-LNBR Part L: Roofs — covers structural requirements, waterproofing performance, fire resistance, and thermal insulation for all building types.
SANS 10137:2005Steel roof and wall cladding — covers material grades, profiles, fixing specifications, side and end laps, and performance requirements for different wind zones.
NHBRC Home Building ManualFor residential projects: sets minimum standards for roof structures, waterproofing, and thermal performance. All roof defects fall under the 5-year structural warranty.

Roofing Method Statement FAQ

Do I need NHBRC registration for government housing roofing tenders?
Yes, if the project involves residential units (RDP housing, social housing, community residential units). NHBRC registration is mandatory for all home builders and the roof structure falls under the 5-year major structural defect warranty.
What fall protection is required during roofing work?
Per Construction Regulation 10, a written fall protection plan is mandatory. For roof edges: guardrails or scaffold at eaves level. For fragile roofs: crawl boards, safety nets, or fall arrest harnesses with overhead anchor points. The plan must cover all phases — including when guardrails are being installed.
How long must a flat roof waterproof guarantee last?
Government tenders typically specify 10-year guarantees for waterproofing, sometimes 15 years for critical facilities. The guarantee must be backed by both the applicator (your company) and the membrane manufacturer. Both must be named in the tender submission.
What is the SATAS approval requirement for waterproofing?
SATAS (SA Technical Auditing Services) tests and certifies waterproofing membrane systems. Government and NHBRC specifications require SATAS-approved systems. The approval number must be referenced in your method statement and product data sheets submitted with the tender.

Generate Your Roofing Method Statement Now

Stop spending hours on documentation. Our AI creates tender-ready method statements in minutes.

Start Free - No Card Required